× ABONNEREN

Met CAD/CAM-technologie vervaardigde kroon vergeleken

1 maart 2014 Geen reacties

Regelmatig verschijnen er artikelen over onderzoek waarin kronen die op de traditionele zijn vervaardigd werden vergeleken met kronen waarvoor de CAD/CAM technologie werd gebruikt.
In een van deze onderzoeken is bij beide technieken nagegaan in hoeverre de marginale pasvorm van de keramische kroon verschilt

The purpose of this study was to assess in vivo the marginal fit of single crowns produced using two CAD/CAM all-ceramic systems, in comparison to more traditional metal ceramic crowns. Materials and Methods: Thirty vital, caries-free, and previously untreated teeth were chosen in five patients who needed extraction for implant placement and therefore were included in this study. In the control group (C), 10 regular metal ceramic crowns with porcelain occlusal surfaces were fabricated. In the other two groups (Z and E), CAD/CAM technology was used for the fabrication of 20 zirconium-oxide-based ceramic single crowns with two systems. All zirconia crowns were cemented with glass-ionomer cement, always following the manufacturer's instructions. The same dentist carried out all clinical phases. The teeth were extracted 1 month later. Marginal gaps along vertical planes were measured for each crown, using a total of four landmarks for each tooth by means of a microscope at a magnification of 50×. On completion of microscopic evaluation, representative specimens from each group were prepared for ESEM evaluation. Mean and standard deviations of the four landmarks (mesial, distal, buccal, palatal) at each single crown were calculated for each group. Multivariate analysis of variance (MANOVA) was performed to determine whether the four landmarks, taken into consideration together, differed between groups. Two-way ANOVA was performed to study in detail, for each landmark, how the three systems used to produce the FPDs affected the gap measurements. Differences were considered to be significant at p < 0.05. Results: MANOVA revealed no quantitative differences of the four landmarks, when taken into consideration together, between the three groups (p < 0.0001). Two-way ANOVA, performed at each landmark, revealed no quantitative differences between the three groups (p < 0.0001 for each landmark). Conclusions: Within the limitations of this study, it was concluded that the two zirconium-oxide-based ceramic CAD/CAM systems demonstrated a similar and acceptable marginal fit when compared to more traditional metal ceramic crowns.

Bron
Biscaro L, Bonfiglioli R, Soattin M, Vigolo P. An in vivo evaluation of fit of zirconium-oxide based ceramic single crowns, generated with two CAD/CAM systems, in comparison to metal ceramic single crowns. J Prosthodont 2013; 22: 36-41. doi: 10.1111/j.1532-849X.2012.00907.x. Epub 2012 Sep 4.

Winkelmandje

Er zitten geen programma's in het winkelmandje